A finger touching a USB port, a button or a terminal block can put thousands of volts onto your board. The discharge lasts a few tens of nanoseconds, but the current has to go somewhere, and if the layout does not give it a short path to ground it will find a longer one through a microcontroller pin.
What the standard asks for
IEC 61000-4-2 defines the test. The generator models a charged person: 150 pF discharged through 330 Ω. The current rises in under a nanosecond, and an 8 kV contact discharge produces a first peak of about 30 A. The test levels are:
- Level 1: 2 kV contact, 2 kV air
- Level 2: 4 kV contact, 4 kV air
- Level 3: 6 kV contact, 8 kV air
- Level 4: 8 kV contact, 15 kV air
Many products target level 2 or level 3 contact, and level 4 where users touch connectors often. The target comes from the product’s standard and the customer, not from the diode we like.
Where the TVS goes
A TVS clamps only if the current path through it is shorter than the path through the chip. So:
- Place it at the connector, before any series resistor, ferrite or filter, with the signal trace passing across its pad.
- Connect its ground side to the ground plane with a short, wide trace and a via right at the pad. Inductance is the enemy: roughly 1 nH per millimetre of trace is a useful figure, and at an edge rate of 1 ns each nanohenry adds volts.
- For high-speed lines such as USB, pick a low-capacitance array rated for the interface. A large general-purpose TVS will close the eye diagram.
The return path
The zap current does not vanish at the TVS. It flows into the ground plane and back to the source, often through the enclosure or a cable shield. We keep a solid ground plane under the connector area, tie the connector shell to chassis ground, and join chassis to signal ground at one controlled point, often through a small resistor in parallel with a capacitor. Keep sensitive traces and the oscillator away from that return path.
Buttons and plastic housings
A button behind a plastic cap may never be touched by a spark, but air discharge finds seams. We keep traces from the button short, add a small series resistor and a capacitor to ground at the input, and put the board’s ground ring near the button opening.
What a TVS does not fix
A TVS clamps to a voltage that can still exceed a pin’s absolute maximum, so a series resistor or a part with built-in ESD tolerance is usually needed too. ESD protection also does not cover surge, which is a longer, higher-energy event covered by IEC 61000-4-5. Final confidence comes from a test at a lab, not from the schematic.
If a product keeps failing ESD tests or dying at the connector, book a discovery call and send us the layout. Our PCB design work includes ESD review.